亚洲熟妇无码爱V在线观看_亚洲国产精品无码久久久蜜芽_久久精品欧美国产综合A_伊人久久精品一区二区_99久久无码精品一区二区三区_久久精品一区二区曰韩AV

歡迎來(lái)到保定市英格索蘭空壓機(jī)有限公司網(wǎng)站!

公司簡(jiǎn)介| 設(shè)為首頁(yè)| 聯(lián)系我們|

英格索蘭百年企業(yè) 值得信賴(lài)的節(jié)能專(zhuān)家 傳,智慧創(chuàng)新--承,優(yōu)良品質(zhì)

服務(wù)熱線

138-3328-1195

當(dāng)前位置:首頁(yè) > 新聞中心 > 公司新聞

空壓機(jī)***操作程序和注意事項(xiàng)

發(fā)布者:wubaiyi    發(fā)布時(shí)間:2020-11-04

空壓機(jī)是不少企業(yè)主要的機(jī)械動(dòng)力設(shè)備之一,保持空壓機(jī)***操作是非常必要的。嚴(yán)格執(zhí)行空壓機(jī)操作規(guī)程,不僅有助于延長(zhǎng)空壓機(jī)的使用壽命,而且能確??諌簷C(jī)操作人員***,下面我們來(lái)了解一下空壓機(jī)操作規(guī)程。 Air compressor is one of the main mechanical and power equipment in many enterprises, so it is very necessary to maintain safe operation of air compressor. Strictly executing the operating rules of the air compressor not only helps to prolong the service life of the air compressor, but also ensures the safety of the operating personnel of the air compressor. Here we will understand the operating rules of the air compressor. 1.1 空壓機(jī)開(kāi)車(chē)前認(rèn)真檢查油氣分離器油位并檢查有無(wú)泄漏,停車(chē)油位應(yīng)位于油位標(biāo)記的2/3,當(dāng)停車(chē)時(shí)油位低時(shí)要補(bǔ)充潤(rùn)滑油,嚴(yán)禁低油位開(kāi)車(chē)。 1.1 air compressor carefully check oil gas separator oil level before driving and check if there is leakage, the parking oil level should be located in the oil level marked 2/3, when parking low oil level should be supplemented with lubricating oil, strictly prohibit low oil level driving. 1.2 檢查空壓機(jī)出口管道與壓縮冷空氣儲(chǔ)罐之間暢通,所有必要閥門(mén)打開(kāi),嚴(yán)禁出口閥門(mén)在關(guān)閉狀態(tài)下開(kāi)啟空壓機(jī),造成螺桿超壓運(yùn)行。 1.2 check the outlet pipe of the air compressor and the compressed cold air tank, all the necessary valves are opened, and the outlet valve is strictly forbidden to open the air compressor in the closed state, causing the screw overpressure to run. 1.3 檢查控制面板有無(wú)維護(hù)指示,如有,通知維修部門(mén)進(jìn)行維護(hù)。 1.3 check whether the control panel has maintenance instructions, if necessary, inform the maintenance department for maintenance. 1.4 檢查驅(qū)動(dòng)電機(jī)正反轉(zhuǎn)方向,主要是電源接線相序變化時(shí),**點(diǎn)動(dòng)試轉(zhuǎn),以免電機(jī)反轉(zhuǎn)造成危險(xiǎn)及損壞設(shè)備。 1.4 check that the driving motor is in the direction of reversing, mainly when the power supply wiring phase sequence changes, it is necessary to move the test circuit to avoid the danger of motor reversing and damage the equipment. 1.5 開(kāi)車(chē)時(shí)先打開(kāi)空壓機(jī)出口閥門(mén),關(guān)閉冷凝液排污閥,接通空壓機(jī)電源。 1.5 turn on the outlet valve of the air compressor, turn off the condensate drain valve and connect the air compressor power supply when driving. 1.6 按下電源復(fù)位鍵,控制面板上出現(xiàn)“準(zhǔn)備開(kāi)車(chē)”。 1.6 press the power reset button and "ready to drive" appears on the control panel. 1.7 按開(kāi)車(chē)鍵開(kāi)車(chē),壓縮機(jī)加載運(yùn)行,設(shè)定空壓機(jī)的加載及卸載壓力需在合適的區(qū)間內(nèi)。一般兩者壓力差要求大于0.6bar,以免空壓機(jī)頻繁加載和卸載。 1.7 press the start button to start the compressor. When the compressor is loaded, the loading and unloading pressure of the air compressor should be set in the appropriate interval. Generally, the pressure difference between the two is greater than 0.6bar, so as to avoid frequent loading and unloading of air compressors. 1.8 每班檢查一次控制屏上排氣壓力、排氣溫度、運(yùn)行狀態(tài)、故障報(bào)警、保養(yǎng)信息等參數(shù)及信息,一旦發(fā)現(xiàn)有維護(hù)提示及時(shí)通知維修部門(mén)進(jìn)行處理。 1.8 check the parameters and information of the exhaust pressure, exhaust temperature, running state, fault alarm and maintenance information on the control screen once in each class. Once the maintenance tips are found, the maintenance department is promptly informed of the maintenance department to deal with it. 1.9 每班**至少一次手動(dòng)對(duì)空壓機(jī)出口管道、壓縮空氣儲(chǔ)罐、過(guò)濾器底部排水。 1.9 every shift must be manually drained to the outlet of the air compressor, compressed air storage tank and filter bottom at least once. 1.10 空壓機(jī)房溫度控制 35℃以下,空壓機(jī)排氣溫度控制在75-95℃之間,避免冷凝水析出將油乳化。 1.10 the temperature of the air compressor room is controlled below 35 C. the exhaust temperature of the air compressor is controlled between 75-95 degrees, so that the condensate can be avoided to emulsify the oil. 1.11 任何時(shí)候**保證至少一臺(tái)空壓機(jī)運(yùn)行,給消防報(bào)警閥室消防設(shè)備提供壓縮空氣。 1.11 at any time, we must ensure that at least one air compressor runs and provide compressed air to the fire alarm valve room fire control equipment. 1.12 ??諌簷C(jī)時(shí)按下停車(chē)鍵,需要 30s 延時(shí),關(guān)閉出口排氣閥。 1.12 when the air compressor is stopped, pressing the stop button will require 30s delay and close the outlet exhaust valve. 1.13 切斷電源,并手動(dòng)排污數(shù)次。 1.13 cut off the power supply and discharge the sewage several times manually. 1.14 緊急狀態(tài),按下屏幕上紅色緊急停車(chē)按鍵,嚴(yán)禁使用。 1.14 emergency, press the red emergency stop button on the screen, and strictly prohibit use. 1.15 每周一白班更換一次空壓機(jī)和冷干機(jī)運(yùn)行順序,先啟動(dòng)一臺(tái)運(yùn)行正常后再停止另一臺(tái)??諌簷C(jī)停止后用壓縮空氣吹掃冷干機(jī)和空壓機(jī)的散熱片;檢查油位不低于視鏡的下三分之一處,必要時(shí)進(jìn)行加油。 1.15 change the running sequence of air compressor and chill machine every Monday on the day shift. First start one and run normally, then stop another one. After the air compressor is stopped, use the compressed air to blow out the radiator of the cold dry machine and the air compressor; check the oil level not less than the lower 1/3 of the mirror, and fill the gas when necessary. 1.16 每周一白班值班長(zhǎng)安排清潔人員打掃空壓機(jī)房地面和設(shè)備表面衛(wèi)生,避免塵土產(chǎn)生。 1.16 every Monday, the duty squad leader arranges the cleaning personnel to clean the surface of the air compressor room and the surface of the equipment so as to avoid dust generation.

推薦資訊 / Recommended News

推薦產(chǎn)品
聯(lián)系我們

電話:0312-2195386
聯(lián)系人:賈經(jīng)理
地址:保定市興業(yè)路289號(hào)